Reactive Energy Converter
Convert reactive power and energy units, calculate reactive power from voltage, current, and power factor with our free online tool.
Reactive Power (Q) Converter
Example: Convert 500 VAR to kVAR
Reactive Energy (Q·h) Converter
Example: Convert 1000 VAR·h to kVAR·h
Reactive Power from V, I & Power Factor
Example: Single-phase, V=230V, I=10A, PF=0.85
Reactive Energy from Q & Time
Example: Q=5 kVAR, Time=24 hours
Free Online Reactive Energy Converter
Our Reactive Energy Converter is a powerful online tool that helps electrical engineers, technicians, and students convert between reactive power units and calculate reactive power from basic electrical parameters. With intuitive controls and accurate calculations, working with reactive power has never been easier.
Unit Conversion
Convert between VAR, kVAR, and MVAR units
Power Calculation
Calculate reactive power from V, I & power factor
Energy Calculation
Calculate reactive energy from power and time
Examples Included
Learn with practical examples for each calculation
Fast Calculations
Get instant results with our optimized calculation engine for all your reactive power needs.
Mobile Friendly
Works seamlessly on all devices, from desktop to mobile, so you can calculate anywhere.
Privacy Focused
Your data is processed locally and never stored on our servers. Your calculations remain private.
Reactive Energy Converter – Frequently Asked Questions
Find answers to common questions about reactive power, energy conversion, and calculations. Learn how to use our free online tool effectively.
Reactive power (measured in VAR, kVAR, or MVAR) is the power that oscillates between the source and load in AC systems, while active power (measured in Watts) is the actual power consumed. Reactive power doesn’t perform useful work but is necessary for maintaining voltage levels and enabling the operation of inductive loads like motors and transformers. Our tool helps you convert between different units of reactive power and energy.
Our Reactive Energy Converter processes your input values using standard electrical formulas. For unit conversion, it multiplies/divides by conversion factors (1 kVAR = 1000 VAR, 1 MVAR = 1000 kVAR). For reactive power calculation, it uses Q = √3 × V × I × sin(φ) for three-phase systems or Q = V × I × sin(φ) for single-phase systems, where φ is the phase angle derived from the power factor.
VAR (Volt-Ampere Reactive) is the base unit of reactive power. kVAR (kilovolt-ampere reactive) equals 1,000 VAR, and MVAR (megavolt-ampere reactive) equals 1,000,000 VAR. These units measure the reactive component of power in electrical systems. Our converter allows easy conversion between these units for various applications in power system analysis.
To calculate reactive power (Q) from voltage (V), current (I), and power factor (PF), first find the phase angle: φ = cos⁻¹(PF). Then calculate Q = V × I × sin(φ) for single-phase systems, or Q = √3 × V × I × sin(φ) for three-phase systems. Our tool automates this calculation – just input your values and select single or three-phase configuration.
Power factor (PF) is the ratio of active power to apparent power, ranging from 0 to 1. A lower PF indicates more reactive power in the system. When PF = 1, all power is active; when PF = 0, all power is reactive. Industrial facilities often use capacitor banks to improve power factor by supplying reactive power locally, reducing the reactive power drawn from the grid.
Yes, our tool supports both single-phase and three-phase systems. Simply select your system type in the “Reactive Power from V, I & Power Factor” calculator. For three-phase systems, ensure you’re using line voltage and line current values. The tool automatically applies the correct formula (including the √3 factor for three-phase calculations).
Yes, your data is completely secure. All calculations happen locally in your browser – your electrical data never leaves your computer or gets sent to any server. This ensures complete privacy and security for your electrical system parameters. We don’t store or have access to any values you process with our tool.
To convert from VAR·h to kVAR·h, divide the value by 1,000. For example, 5,000 VAR·h = 5 kVAR·h. Our converter automates this process – simply enter your value, select “VAR·h” as the “From” unit and “kVAR·h” as the “To” unit, then click “Convert”. The tool handles all unit conversions instantly.
Reactive power compensation is crucial because excessive reactive power flow causes higher line currents, increased losses, voltage drops, and reduced system capacity. By installing capacitors or other compensation devices near inductive loads, facilities can provide reactive power locally, improving power factor and reducing the burden on the electrical distribution system.
Yes, our Reactive Energy Converter is completely free to use with no hidden costs or limitations. You can perform unlimited conversions and calculations without any registration or payment requirements. We’re committed to providing free, useful tools for electrical engineers, technicians, and students.
Need More Help?
Contact Support
Get direct help from our team
Our support team is available to answer any specific questions about using the Reactive Energy Converter.
Contact SupportComprehensive Guide
Learn more about reactive power
Read our comprehensive blog post that explains reactive power concepts, calculations, and practical applications in electrical systems.
Read Blog PostVideo Tutorials
Watch how-to videos
Learn how to use all features of our Reactive Energy Converter with visual guides and practical examples.
More Tools
Explore our tool collection
Discover other useful electrical engineering and power calculation tools in our collection.
Browse ToolsPower Calculations
Learn about different power calculation methods
Use Cases
Discover practical applications for reactive power calculations
Tips & Tricks
Get the most out of our reactive energy converter